<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-30 23-43-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 4/5, 56 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 2.8 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 61 kHz 16253 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,6 dBr 1,83 dBr 3,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Marchenbilder Alttoviululle Ja Pianolle Op. 113 (Schumann R) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 61 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/07/30 23.42.42 Total samples: 16253 Equivalent time: 0:13:32 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 3,1 dBr MIN: -0,6 dBr AVE: 1,83 dBr % above 12,2 dBr: 0,0 Last value: 2,3 dBr (2025/07/30 23.42.41) 23.28 23.30 23.32 23.34 23.36 23.38 23.40 23.42 -1 0 1 2 3 4 Pm [dBr]